QHow just eye balling pulse oximetry on monitor can help in diagnosis of patient having suspicion of cardiac tamponade?


Answer: Patients with suspicion of cardiac tamponade, usually show increased respiratory variability in pulse-oximetry waveform.


Reference:


Stone MK, Bauch TD, Rubal BJ. Respiratory changes in the pulse-oximetry waveform associated with pericardial tamponade. Clin Cardiol. Sep 2006;29(9):411-4